Delivery Time: 3 Days
Basic Info

Model No.: SSV

Product Description  SSV sereies   Two Way Solenoid Valve Bi-flow solenoid valve  
    Specification:   Solenoid valve technical data:   Ambient temperature: -20 ~ 50°C   Liquid temperature: -25 ~ 120°C   Max. working pressure: 3MPa   Max. testing pressure: 3.5MPa   Available medium: R134a,R22,R407C,R404A/507   Rated power:    A.C.: 24V,36V,110V,220V,380V    D.C.: 12V,24V,110V,220V    

Connection  form

Model

Connection  dimension              

Kvvalue   (m3/h)

Opening diff. pressure                    (MPa)

dimension   

        (mm)

 (mm)

 (in.)

Min.

Max.

A.C.

D.C.

Length

Wide

Height

Flare

SAE

SSV6

Φ8

5/16

0.4

0.01

2.1

1.7

85

45

97

SSV8

Φ10

3/8

1

85

45

97

SSV10A

Φ12

1/2

1.8

85

45

97

SSV13A

Φ16

5/8

3

89

45

97

SSV16

Φ19

3/4

4.5

118

60

120

SSV19

Φ22

7/8

5

118

60

120

 

 

 

 

 

 

 

 

 

 

 

Solder ODF

SSV6W

Φ8

5/16

0.4

126

45

97

Φ10

3/8

Φ12

1/2

SSV8W

Φ10

3/8

1

126

45

97

Φ12

1/2

SSV10AW

Φ12

1/2

1.8

126

45

97

Φ16

5/8

SSV13AW

Φ16

5/8

3

150

45

97

Φ19

3/4

Φ22

7/8

SSV16W

Φ19

3/4

4.5

190

60

120

Φ22

7/8

SSV19W

Φ22

7/8

5

190

60

120

Φ25

1

Φ28

1-1/8

SSV25W

Φ28

1-1/8

9.5

0.03

240

72

120

Φ32

1-1/4

240

72

120

Φ35

1-3/8

SSV32W

Φ35

1-3/8

15

260

86

130

Φ42

1-5/8

260

86

130

Φ48

1-7/8

Φ54

2-1/8

The Kv value is the water flow in m3/h at a pressure drop across valve of 0.1Mpa,ρ=1000kg/m3

Letters after the model: “A” means improved typr, “W” means solder ODF. “K” means normal opened valves.

    Introduction: SSV series two-way Bi-flow Solenoid Valves are mainly used for the defrosting of wind cooling heat pump refrigeration unit and the defrosting of supermarket refrigerators as well.  the adoption of SSV series can reduce the amount of check valves and Solenoid Valves in the refrigeration system, which makes system pipeline designs more reasonable     Operation principle:  When the coil is energized, the electromagnetic power opens the small orifice. Then the  pressure in upside of valve will reduce, the pressure difference between both side of diaphragm  happens and make diaphragm lift to open the main orifice.When the coil is de-energized,the plug stem will drop and close the small orifice because of  spring force and its weight. The medium enters into upside of diaphrgm through throttle hole, then the pressure  in both side of diaphragm will downside.Finally  the diaphragm will drop and close the main  orifice.     Attention when use SV series solenoid valve: 1. The valve must install in horizontal pipe line under vertical position. The flow direction must  meet the arrow direction in valve body. 2. The oil input voltage must meet rated input voltage showed on the label. Departure coil from  valve when energized in coil is not permitted in order to avoid damage the coil. 3. According to valve with manual function, it must turn manual bar to open the valve before  doing system air tightness in order to avoid to damage diaphragm. 4. When brazing the valve with connect tube in system, follow points are very important:   a. Before brazing, coil must be departure and use wet fabric cover the valve body to avoid to  damage valve part because of high temperature when brazing. b. It must avoid the brazing flame face to valve body. c. It is better to adopt low temperature type silver brazing bar. 5. According to valve with manual function. The manual bar must be turned to open the valve  before doing system air tightness, in order to avoid to damage the diaphragm. 6. Coil must be set to the body when the current on.     Factory Overview:    

Contact us if you need more details on 2 Way Solenoid Valve. We are ready to answer your questions on packaging, logistics, certification or any other aspects about 3 Way Solenoid Valve、24v Solenoid Valve. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Water Regulating Valves > Pressure Controlled Water Valves